Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 137
Filtrar
2.
Artigo em Inglês | MEDLINE | ID: mdl-38662508

RESUMO

PURPOSE OF REVIEW: Endoscopy-related injuries (ERIs) are prevalent in gastrointestinal endoscopy. The aim of this review is to address the growing concern of ERIs by evaluating the ergonomic risk factors and the efficacy of interventions and educational strategies aimed at mitigating these risks, including novel approaches. RECENT FINDINGS: ERIs are highly prevalent, exacerbated by factors such as repetitive strain, nonneutral postures, suboptimal equipment design, and the procedural learning curve. Female sex and smaller hand sizes have been identified as specific risk factors. Recent guidelines underscore the importance of ergonomic education and the integration of ergonomic principles into the foundational training of gastroenterology fellows. Advances in equipment design focus on adaptability to different hand sizes and ergonomic positions. Furthermore, the incorporation of microbreaks and macrobreaks, along with neutral monitor and bed positioning, has shown promise in reducing the incidence of ERIs. Wearable sensors may be helpful in monitoring and promoting ergonomic practices among trainees. SUMMARY: Ergonomic wellness is paramount for gastroenterology trainees to prevent ERIs and ensure a sustainable career. Effective strategies include ergonomic education integrated into curricula, equipment design improvements, and procedural adaptations such as scheduled breaks and optimal positioning. Sensor-based and camera-based systems may allow for education and feedback to be provided regarding ergonomics to trainees in the future.

3.
J Can Assoc Gastroenterol ; 7(2): 137-148, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38596798

RESUMO

Background: Interest in patient and public involvement in research has grown. Medical, health, and social care research has demonstrated several benefits of patient and public engagement, such as empowering user input and reducing attrition rates in clinical trials. To date, no study has reviewed patient engagement in inflammatory bowel disease (IBD). We aimed to describe the benefits, challenges, and best practices of patient engagement in IBD research. Methods: We performed a systematic search on MEDLINE, EMBASE, and Cochrane for all clinical IBD research studies in which patients were involved in the research process (1946- 2023). Patient input was considered in: (1) study design, (2) study execution, (3) research dissemination, and/or (4) other domains not specified here. Two authors independently screened and extracted data on type of engaged person(s), format of engagement, author-reported benefits, recommendations, and challenges. For each study, we reported the level of patient engagement and study adherence to standardized reporting guidelines. Results: After screening 9,355 articles, we included 51 for final analysis. IBD patients were most frequently engaged in study design. Patient engagement in IBD research improved recruitment rates and promoted the creation of user-friendly quality-of-life tools. Selection bias and recruitment difficulties were common challenges in the application of patient engagement. Authors recommended continuous patient involvement to address emerging priorities and cognitive interviewing to improve questionnaire clarity. Conclusions: Patient engagement represents an important step in promoting patient-centred care. According to study authors, implementing cognitive interviewing techniques, continuous patient involvement, and standardized reporting guidelines may improve future iterations of engagement in IBD.

5.
Gastroenterology ; 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38513744

RESUMO

BACKGROUND & AIMS: Significant variability exists in colonoscopy quality indicators, including adenoma detection rate (ADR). We synthesized evidence from randomized trials in a network meta-analysis on interventions to improve colonoscopy quality. METHODS: We included trials from database inceptions to September 25, 2023, of patients undergoing screening-related colonoscopy and presented efficacies of interventions within domains (periprocedural parameters, endoscopist-directed interventions, intraprocedural techniques, endoscopic technologies, distal attachment devices, and additive substances) compared to standard colonoscopy. The primary outcome was ADR. We used a Bayesian random-effects model using Markov-chain Monte Carlo simulation, with 10,000 burn-ins and 100,000 iterations. We calculated odds ratios with 95% credible intervals and present surface under the cumulative ranking (SUCRA) curves. RESULTS: We included 124 trials evaluating 37 interventions for the primary outcome. Nine interventions resulted in statistically significant improvements in ADR compared to standard colonoscopy (9-minute withdrawal time, dual observation, water exchange, iScan, linked color imaging, computer-aided detection, Endocuff, Endocuff Vision, and oral methylene blue). Dual observation (SUCRA, 0.84) and water exchange (SUCRA, 0.78) ranked highest among intraprocedural techniques; iScan (SUCRA, 0.95), linked color imaging (SUCRA, 0.85), and computer-aided detection (SUCRA, 0.78) among endoscopic technologies; WingCap (SUCRA, 0.87) and Endocuff (SUCRA, 0.85) among distal attachment devices and oral methylene blue (SUCRA, 0.94) among additive substances. No interventions improved detection of advanced adenomas, and only narrow-band imaging improved detection of serrated lesions (odds ratio, 2.94; 95% credible interval, 1.46-6.25). CONCLUSIONS: Several interventions are effective in improving adenoma detection and overall colonoscopy quality, many of which are cost-free. These results can inform endoscopists, unit managers, and endoscopy societies on relative efficacies.

6.
Gastrointest Endosc ; 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38331224

RESUMO

BACKGROUND AND AIMS: Resection of colorectal polyps has been shown to decrease the incidence and mortality of colorectal cancer. Large non-pedunculated colorectal polyps are often referred to expert centres for endoscopic resection, which requires relevant information to be conveyed to the therapeutic endoscopist to allow for triage and planning of resection technique. The primary objective of our study was to establish minimum expected standards for the referral of LNPCP for potential ER. METHODS: A Delphi methodology was employed to establish consensus on minimum expected standards for the referral of large colorectal polyps among a panel of international endoscopy experts. The expert panel was recruited through purposive sampling, and three rounds of surveys were conducted to achieve consensus, with quantitative and qualitative data analysed for each round. RESULTS: A total of 24 international experts from diverse continents participated in the Delphi study, resulting in consensus on 19 statements related to the referral of large colorectal polyps. The identified factors, including patient demographics, relevant medications, lesion factors, photodocumentation and the presence of a tattoo, were deemed important for conveying the necessary information to therapeutic endoscopists. The mean scores for the statements ranged from 7.04 to 9.29 out of 10, with high percentages of experts considering most statements as a very high priority. Subgroup analysis by continent revealed some variations in consensus rates among experts from different regions. CONCLUSION: The identified consensus statements can aid in improving the triage and planning of resection techniques for large colorectal polyps, ultimately contributing to the reduction of colorectal cancer incidence and mortality.

8.
Endosc Int Open ; 12(1): E99-E107, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38250163

RESUMO

Background and study aims Cold-snare polypectomy (CSP) is considered the standard of care for resection of colorectal polyps ≤10 mm. Data on the efficacy of CSP performed with thin-wire snares compared0 with thick-wire snares are conflicting. We performed a meta-analysis comparing complete resection (CR) and adverse event rates of CSP using thin-wire and thick-wire snares. Patients and methods Comparative studies of adult patients with ≧1 colorectal polyp(s) ≦10 mm who underwent CSP with thin-wire or thick-wire snares were included. We collected data on study, patient, polyp, and snare characteristics. The primary outcome was CR rate. Secondary outcomes were polyp retrieval rate, intraprocedural bleeding, delayed post-polypectomy bleeding, deep mural injury or perforation, patient discomfort, total sedation, and procedure time. We used random-effects models to calculate risk ratios for outcomes. We performed risk of bias assessments, rated the certainty of evidence, and assessed publication bias for all studies. Results We included four randomized controlled trials (RCTs) and two observational studies including 1316 patients with 1679 polyps (826 thin-wire CSPs and 853 thick-wire CSPs). There was no significant difference between thin-wire CSP (92.1%) and thick-wire CSP (87.7%) for RCTs (risk ratio [RR] 1.05, 95% confidence interval [CI] 0.94-1.16) or observational studies (78.1% versus 79.6%, RR 1.03, 95% CI 0.99-1.08). There were no significant differences in polyp retrieval rate or intraprocedural bleeding. There were no cases of delayed bleeding or perforation. Conclusions We found no differences in CR rates for CSP between thin-wire and thick-wire snares. CSP, regardless of snare type, is safe and effective for resection of small colorectal polyps.

9.
Gastrointest Endosc ; 99(4): 633-640, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38092126

RESUMO

BACKGROUND AND AIMS: The incidence, risk factors, and outcomes of post-ERCP cholecystitis are poorly described. We aimed to describe cases of post-ERCP cholecystitis from a prospective multicenter registry with protocolized 30-day follow-up. METHODS: Patient- and procedure-related data from 7 centers were obtained. The primary outcome was post-ERCP cholecystitis, defined according to a Delphi-based criteria and causal attribution system. Risk factors and outcomes were described for all cases. RESULTS: Seventeen cases of post-ERCP cholecystitis were identified among 4428 patients with gallbladders undergoing ERCP between 2018 and 2023 (incidence, 0.38%; 95% confidence interval, 0.20-0.57). In ERCPs with covered metal stenting, 7 of 467 resulted in cholecystitis (incidence, 1.50%; 95% confidence interval, 0.40-2.60). Patients had symptoms at a median of 5 days (interquartile range, 5) after ERCP. Management strategies included cholecystectomy, percutaneous cholecystostomy, and endoscopic stent removal/exchange. CONCLUSIONS: Estimates of post-ERCP cholecystitis incidence can inform discussions around procedural risk.


Assuntos
Sistema Biliar , Colecistite , Humanos , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Colecistite/epidemiologia , Colecistite/etiologia , Incidência , Estudos Prospectivos , Estudos Retrospectivos , Estudos Multicêntricos como Assunto
10.
G3 (Bethesda) ; 14(3)2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38142435

RESUMO

Lingonberry (Vaccinium vitis-idaea L.) produces tiny red berries that are tart and nutty in flavor. It grows widely in the circumpolar region, including Scandinavia, northern parts of Eurasia, Alaska, and Canada. Although cultivation is currently limited, the plant has a long history of cultural use among indigenous communities. Given its potential as a food source, genomic resources for lingonberry are significantly lacking. To advance genomic knowledge, the genomes for 2 subspecies of lingonberry (V. vitis-idaea ssp. minus and ssp. vitis-idaea var. 'Red Candy') were sequenced and de novo assembled into contig-level assemblies. The assemblies were scaffolded using the bilberry genome (Vaccinium myrtillus) to generate a chromosome-anchored reference genome consisting of 12 chromosomes each with a total length of 548.07 Mb [contig N50 = 1.17 Mb, BUSCO (C%) = 96.5%] for ssp. vitis-idaea and 518.70 Mb [contig N50 = 1.40 Mb, BUSCO (C%) = 96.9%] for ssp. minus. RNA-seq-based gene annotation identified 27,243 and 25,718 genes on the respective assembly, and transposable element detection methods found that 45.82 and 44.58% of the genome were repeats. Phylogenetic analysis confirmed that lingonberry was most closely related to bilberry and was more closely related to blueberries than cranberries. Estimates of past effective population size suggested a continuous decline over the past 1-3 MYA, possibly due to the impacts of repeated glacial cycles during the Pleistocene leading to frequent population fragmentation. The genomic resource created in this study can be used to identify industry-relevant genes (e.g. anthocyanin production), infer phylogeny, and call sequence-level variants (e.g. SNPs) in future research.


Assuntos
Vaccinium macrocarpon , Vaccinium vitis-Idaea , Vaccinium vitis-Idaea/genética , Filogenia , Vaccinium macrocarpon/genética , Sequência de Bases , Frutas , América do Norte
12.
J Can Assoc Gastroenterol ; 6(6): 212-218, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38106482

RESUMO

Background and study aims: The Paris classification characterizes the morphology of superficial gastrointestinal tract neoplasms. This system has been shown to predict the risk of submucosal invasion in certain subtypes of lesions. There is limited data that assesses its agreement amongst endoscopists. We performed a systematic review to summarize the available literature on the interobserver reliability (IOR) of the Paris classification. Methods: We conducted a search through December 2020 for studies reporting IOR of the Paris classification. Studies were included if they quantitatively evaluated the IOR of the Paris classification with at least five participating endoscopists. Two authors independently screened studies and abstracted data using an a priori-designed data collection form. Evaluation of study quality and risk of bias was performed using an adapted version of the Guidelines for Reporting Reliability and Agreement Studies. Results: Of the 1,541 studies retrieved, 5 were included in the review. All studies were observational cohort studies published between 2014 and 2020. The IOR of the Paris classification was moderate amongst all four studies evaluating colorectal neoplasms (range, κ = 0.42 to κ = 0.54) and substantial in one study that evaluated gastric neoplasms (κw = 0.65). An educational intervention was conducted by three studies with variable methodology and no significant change in IOR. Conclusions: IOR of the Paris classification is moderate for superficial colonic neoplasms. Further study is needed to determine the reliability of this system for superficial gastric lesions. Standardized training programs are required to investigate the impact of educational intervention on the Paris classification amongst endoscopists.

13.
VideoGIE ; 8(12): 520-526, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38155828

RESUMO

Video 1Demonstration of manufacturing instructions and features of the postpolypectomy bleeding and conventional and underwater EMR simulators.

15.
Curr Issues Mol Biol ; 45(8): 6296-6310, 2023 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-37623216

RESUMO

Lingonberry (Vaccinium vitis-idaea L.) is an important and valuable horticultural crop due to its high antioxidant properties. Plant tissue culture is an advanced propagation system employed in horticultural crops. However, the progeny derived using this technique may not be true-to-type. In order to obtain the maximum return of any agricultural enterprise, uniformity of planting materials is necessary, which sometimes is not achieved due to genetic and epigenetic instabilities under in vitro culture. Therefore, we analyzed morphological traits and genetic and epigenetic variations under tissue-culture and greenhouse conditions in lingonberry using molecular markers. Leaf length and leaf width under greenhouse conditions and shoot number per explant, shoot height and shoot vigor under in vitro conditions were higher in hybrid H1 compared to the cultivar Erntedank. Clonal fidelity study using one expressed sequence tag (EST)-polymerase chain reaction (PCR), five EST-simple sequence repeat (SSR) and six genomic (G)-SSR markers revealed monomorphic bands in micropropagated shoots and plants in lingonberry hybrid H1 and cultivar Erntedank conforming genetic integrity. Epigenetic variation was studied by quantifying cytosine methylation using a methylation-sensitive amplification polymorphism (MSAP) technique. DNA methylation ranged from 32% in greenhouse-grown hybrid H1 to 44% in cultivar Erntedank under a tissue culture system. Although total methylation was higher in in vitro grown shoots, fully methylated bands were observed more in the greenhouse-grown plants. On the contrary, hemimethylated DNA bands were more prominent in tissue culture conditions as compared to the greenhouse-grown plants. The study conclude that lingonberry maintains its genetic integrity but undergoes variable epigenetic changes during in vitro and ex vitro conditions.

16.
J Clin Med ; 12(13)2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37445437

RESUMO

Tranexamic acid (TXA), a synthetic antifibrinolytic drug, has proven efficacy and is recommended for major pediatric surgery to decrease perioperative blood loss. Accumulating evidence suggests that TXA reduces bleeding and transfusion in a variety of adult neurosurgical settings. However, there is a paucity of research regarding TXA indications for pediatric neurosurgery and thus, there are currently no recommendations for its use with this specific population. The objective of this study is to evaluate the existing practice of TXA administration for pediatric neurosurgery at a U.S. tertiary care pediatric hospital over a five-year period. The authors conclude that TXA administration is feasible and should be considered for pediatric neurosurgical cases where potential blood loss is a concern.

17.
PLoS One ; 18(7): e0288474, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37440486

RESUMO

PURPOSE: Self-assessment of a physician's performance in both procedure and non-procedural activities can be used to identify their deficiencies to allow for appropriate corrective measures. Physicians are inaccurate in their self-assessments, which may compromise opportunities for self- development. To improve this accuracy, video-based interventions of physicians watching their own performance, an experts' performance or both, have been proposed to inform their self-assessment. We conducted a systematic review of the effectiveness of video-based interventions targeting improved self-assessment accuracy among physicians. MATERIALS AND METHODS: The authors performed a systematic search of MEDLINE, Embase, EBM reviews, and Scopus databases from inception to August 23, 2022, using combinations of terms for "self-assessment", "video-recording", and "physician". Eligible studies were empirical investigations assessing the effect of video-based interventions on physicians' self-assessment accuracy with a comparison of self-assessment accuracy pre- and post- video intervention. We defined self-assessment accuracy as a "direct comparison between an external evaluator and self-assessment that was quantified using formal statistical analysis". Two reviewers independently screened records, extracted data, assessed risk of bias, and evaluated quality of evidence. A narrative synthesis was conducted, as variable outcomes precluded a meta-analysis. RESULTS: A total of 2,376 papers were initially retrieved. Of these, 22 papers were selected for full-text review; a final 9 studies met inclusion criteria for data extraction. Across studies, 240 participants from 5 specialties were represented. Video-based interventions included self-video review (8/9), benchmark video review (3/9), and/or a combination of both types (1/9). Five out of nine studies reported that participants had inaccurate self-assessment at baseline. After the intervention, 5 of 9 studies found a statistically significant improvement in self-assessment accuracy. CONCLUSIONS: Overall, current data suggests video-based interventions can improve self-assessment accuracy. Benchmark video review may enable physicians to improve self-assessment accuracy, especially for those with limited experience performing a particular clinical skill. In contrast, self-video review may be able to provide improvement in self-assessment accuracy for more experience physicians. Future research should use standardized methods of comparison for self-assessment accuracy, such as the Bland-Altman analysis, to facilitate meta-analytic summation.


Assuntos
Médicos , Humanos , Autoavaliação (Psicologia) , Competência Clínica
19.
Expert Rev Gastroenterol Hepatol ; 17(6): 589-602, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37158052

RESUMO

INTRODUCTION: Screening-related colonoscopy is a vital component of screening initiatives to both diagnose and prevent colorectal cancer (CRC), with prevention being reliant upon early and accurate detection of pre-malignant lesions. Several strategies, techniques, and interventions exist to optimize endoscopists' adenoma detection rates (ADR). AREAS COVERED: This narrative review provides an overview of the importance of ADR and other colonoscopy quality indicators. It then summarizes the available evidence regarding the effectiveness of the following domains in terms of improving ADR: endoscopist factors, pre-procedural parameters, peri-procedural parameters, intra-procedural strategies and techniques, antispasmodics, distal attachment devices, enhanced colonoscopy technologies, enhanced optics, and artificial intelligence. These summaries are based on an electronic search of the databases Embase, PubMed, and Cochrane performed on 12 December 2022. EXPERT OPINION: Given the prevalence and associated morbidity and mortality of CRC, the quality of screening-related colonoscopy quality is appropriately prioritized by patients, endoscopists, units, and payers alike. Endoscopists performing colonoscopy should be up to date regarding available strategies, techniques, and interventions to optimize their performance.


Assuntos
Adenoma , Neoplasias Colorretais , Humanos , Inteligência Artificial , Colonoscopia , Programas de Rastreamento , Adenoma/diagnóstico por imagem , Adenoma/epidemiologia , Detecção Precoce de Câncer/métodos , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/epidemiologia , Neoplasias Colorretais/patologia
20.
Gastrointest Endosc ; 98(4): 482-491, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37245720

RESUMO

This clinical practice guideline from the American Society for Gastrointestinal Endoscopy provides an evidence-based approach to strategies to prevent endoscopy-related injury (ERI) in GI endoscopists. It is accompanied by the article subtitled "Methodology and Review of Evidence," which provides a detailed account of the methodology used for the evidence review. This document was developed using the Grading of Recommendations Assessment, Development and Evaluation framework. The guideline estimates the rates, sites, and predictors of ERI. Additionally, it addresses the role of ergonomics training, microbreaks and macrobreaks, monitor and table positions, antifatigue mats, and use of ancillary devices in decreasing the risk of ERI. We recommend formal ergonomics education and neutral posture during the performance of endoscopy, achieved through adjustable monitor and optimal procedure table position, to reduce the risk of ERI. We suggest taking microbreaks and scheduled macrobreaks and using antifatigue mats during procedures to prevent ERI. We suggest the use of ancillary devices in those with risk factors predisposing them to ERI.


Assuntos
Endoscopia Gastrointestinal , Ergonomia , Humanos , Postura , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...